TEST: OHIE-CR-13-HL7v2
Patient Demographics Query – Query by mother’s identifier
This test ensures that the recipient of the query can perform a query by the patient’s mother’s identifier.
References
Pre-Conditions / Setup
Setup the receiver such that OID 2.16.840.1.113883.3.72.5.9.1 has assigning authority of TEST which can be assigned from TEST_HARNESS
Ensure that the following patient is registered in the receiver (can be done with the ADT message provided). Name: Jennifer Jones, id: RJ-439^^^TEST, gender: F, dob: 1984-01-25
MSH|^~\&|TEST_HARNESS^^|TEST^^|CR1^^|MOH_CAAT^^|20141104174451||ADT^A01^ADT_A01|TEST-CR-13-10|P|2.3.1
EVN||20101020
PID|||RJ-439^^^TEST||JONES^JENNIFER^^^^^L|SMITH^^^^^^L|19840125|F|||123 Main Street West ^^NEWARK^NJ^30293||^PRN^PH^^^409^30495||||||
PV1||IEnsure that the following patient is registered in the receiver (can be done with the ADT message provided).RJ-440^^^TEST, gender: M, DOB: 2014-10-01
MSH|^~\&|TEST_HARNESS^^|TEST^^|CR1^^|MOH_CAAT^^|20141104174451||ADT^A01^ADT_A01|TEST-CR-13-15|P|2.3.1
EVN||20101020
PID|||RJ-440^^^TEST||||20141001|M|||||||||||||RJ-439^^^TEST
PV1||ITest Step 1:
Test harness sends a query with mother’s identifier components specified.
Expected Behaviour
Receiver responds with an AA
Receiver sends exactly one PID segment with identifier RJ-440 in domain TEST in PID-3
Test Step 2:
Test harness verifies the infant record was created in the receiver.
Expected Behaviour
Receiver responds with an AA
Receiver sends exactly one PID segment with identifier RJ-440 in domain TEST in PID-3
Last updated