# TEST: OHIE-CR-08-HL7v2

This test ensures that the receiver is able to store and usefully convey (regurgitate) a more complete patient record having multiple names, addresses, telephone numbers, mother’s identifier, mother’s name, birth date, multiple birth order, etc.

## References

## Pre-Conditions / Setup

#### Setup the receiver such that OID 2.16.840.1.113883.3.72.5.9.1 has assigning authority of TEST which can be assigned from TEST\_HARNESS

## Test Step 1:

Test harness sends an ADT^A01 message with complex data set.

```
MSH|^~\&|TEST_HARNESS^^|TEST^^|CR1^^|MOH_CAAT^^|20141104174451||ADT^A01^ADT_A01|TEST-CR-08-10|P|2.3.1
EVN||20101020
PID|||RJ-442^^^TEST||FOSTER^FANNY^FULL^^^^L|FOSTER^MARY^^^^^L|1970|F|||123 W34 St^^FRESNO^CA^30495||^PRN^PH^^^419^31495|^^PH^^^034^059434|EN|S|||||
PV1||I
```

### Expected Behaviour

* Receiver Accepts Message with an AA
* MSH-5 and MSH-6 matches “TEST\_HARNESS|TEST”

## Test Step 2:

Test harness verifies demographics data matches by executing a PDQ query with the patient’s identifier.

```
MSH|^~\&|TEST_HARNESS|TEST|CR1|MOH_CAAT|20090226131520-0600||QBP^Q22^QBP_Q21|TEST-CR-08-30|P|2.5
QPD|Q22^Find Candidates^HL7|Q0740|@PID.3.1^RJ-442~@PID.3.4.1^TEST
RCP|I|10^RD
```

### Expected Behaviour

* Receiver responds with an AA
* Receiver sends exactly one PID segment with identifier RJ-442 in domain TEST in PID-3
* Receiver sends:
  * PID-5=FOSTER^FANNY^FULL^^^^L
  * PID-6=FOSTER^MARY^^^^^L
  * PID-7=1970
  * PID-8=F
  * PID-11=123 W34 St^^FRESNO^CA^20495
  * PID-13=^PRN^PH^^^419^31495
  * PID-14=^^PH^^^034^059434
  * PID-15=EN
  * PID-16=S


---

# Agent Instructions: Querying This Documentation

If you need additional information that is not directly available in this page, you can query the documentation dynamically by asking a question.

Perform an HTTP GET request on the current page URL with the `ask` query parameter:

```
GET https://help.santesuite.org/installation/installation-1/deployment/installing-software/santedb-server/installation-qualification/fhir-interface-validation/mpi-cr-test-cases-for-hl7v2/test-ohie-cr-08-hl7v2.md?ask=<question>
```

The question should be specific, self-contained, and written in natural language.
The response will contain a direct answer to the question and relevant excerpts and sources from the documentation.

Use this mechanism when the answer is not explicitly present in the current page, you need clarification or additional context, or you want to retrieve related documentation sections.