TEST: OHIE-CR-06-HL7v2
Patient Identity Feed – Update based on matching NID
This test ensures that the receiver is able to merge patient data from an assigning authority (TEST_A) which has an national patient identifier (assigning authority NID). The demographics data does not match, this is to test that matching is done on explicit identifiers.
References
Pre-Conditions / Setup
Setup the receiver such that OID 2.16.840.1.113883.3.72.5.9.2 has assigning authority of TEST_A which can be assigned from TEST_HARNESS_A
Setup the receiver such that OID 2.16.840.1.113883.3.72.5.9.9 has assigning authority of NID which can be assigned from NID_AUTH
Ensure that the following patient is registered in the receiver (can be done with the ADT message provided). Name: John Smith, id: NID-000345435^^^NID^NNXXX, gender: M, dob: 1980
Test Step 1:
Test harness (as TEST_HARNESS_A) sends a registration message for patient Jon [sic] Smith having a more specific date of birth, with NID of NID-000345435 and local identifier of TEST_A of RJ-449.
Expected Behaviour
Receiver Accepts Message with an AA
MSH-5 and MSH-6 matches “TEST_HARNESS|TEST”
Test Step 2
Test harness verifies the record was linked with the NID by executing a PIX query
Expected Behaviour
Receiver responds with an AA
Receiver sends exactly one PID segment with identifier RJ-449 in domain TEST_A in one of the PID-3 repetitions
Last updated